Differential Pressure Transmitter
Pressure Gauges
Pressure Transmitters



File Links - Click links to download documentation

Data Sheet
Model AIY5 Drawing




5-Valve Manifold Direct Mount PipeTo Flange - Model AIY5 Generation 200 Series

The Ashford Instrumentation Ltd 5-Valve Manifold Direct Mount Pipe To Flange from our Generation 200 Series is specially designed for a wide range of applications including differential pressure transmitters.

Operation: In normal operation the isolate valves are open while the vent valve and plug are closed. This provides a differential pressure reading to the pressure gauge or transmitter. To zero the instrument, first close both vent valves and the downstream isolate valve. Then open the equalise valve and adjust the zero setting on the instrument. To remove the instrument, first close both isolate valves, then open the equalise valves to relieve pressure between the manifold and the instrument. 

Instrument Calibration:  An option provided by 5-valve manifolds which is not available on 3-valve types is connecting the vent port to known pressure sources to check the calibration of the instrument.